THE ELEMENTS, EXPLAINED

Periodic Tabledevelopment preview

01 / EXPLORE

Elements

118 elements

Select a row or column number to filter.Arrow keys to move · Enter to select

02 / INVESTIGATE

Copper 128 atoms

Copper EAM
PAUSED⁴⁰Ar · 128 atoms
Nanochamber
0.0 pssimulation time
Sample · kinetic293 K
Wall293 K
Readings & files

128 atoms · vacuum · 293.15 K preparation

Packing diagnostic: . This is not a phase measurement.

10.0 µm0.124 eV / photon

The ideal receiver heats the wall, which exchanges energy with the sample, its room-temperature mount and a grey far-field environment. The assumed mount gives cooling when heat is off. These boundaries do not rescale sample velocities.

Measurements No recorded readings

Kinetic sampleWallKinetic estimate (K) / simulation time

Recorded sample readings
Time (ps) Kinetic (K) P (bar) Wall (K)
Pause or run, then record a reading.

Infrared
Beam off
Sample 293 KWall 293 K

Beam off

Beam settings & model
Bulk ref · solid

Off is 0; otherwise 10⁻⁶–10¹⁴ W/m². This is beam power per area, not a temperature setting.

Scientific assumptions & energy

Crucible heats an ideal wall with 80% absorption at every wavelength. Atomic views use a separate isolated-neutral-atom rate model. Atomic photons do not heat the classical crucible.

Uniform atom symbols · translucent gas.

18Ar

03 / UNDERSTAND

Copper

Noble gas · Group 18 · Period 3

No photo

Atomic gas model
More properties

Bulk references do not predict a small cluster's phase.

Compare elements Pin an element

Pin an element with ◇, then select another to compare like-for-like properties.

Try an investigation

Notes stay in this tab. Include them with Save setup.

Sources & model

Element reference

Names and positions follow IUPAC. Atomic-weight intervals follow CIAAW; configurations and selected atomic properties use evaluated reference data. Unknown values remain unknown.

IUPAC periodic table ↗ · CIAAW atomic weights ↗ · NIST atomic data ↗

Chamber model

Copper uses a published interaction potential. Other materials use a labelled cohesive or molecular reference. The atomic gas comparison has no bonding or condensed phases.

The photon gun sets wavelength and intensity. An ideal receiver absorbs 80% at every wavelength; contact and wall collisions heat the sample. This is not a measured element absorption curve. Atom and electron views use a separate isolated-atom excitation reference. Spectrum separates source, thermal and atomic references.

Read the equations and assumptions ↗ · Data provenance ↗

Settings

All views

Drawing modes change symbols, not rates or heating. Device preference follows the device's reduced-motion setting.

Crucible
Light-reference assumptions

LTE assumes thermal electronic populations. Gas symbols use a fixed illustrative exposure of 10⁻¹² W per atom. Neutral excitation can emit without ionisation. Molecular absorption colours, discharge excitation and plasma populations are not calculated. Spectrum identifies the available reference data.

LIGHT REFERENCE

Light spectrum

Beam controls stay available beside this window.

Sample state

Molecule snapshot

Using the table

Choose an element to inspect its identity, electron structure and available properties. Pin one to compare it with another.

The crucible starts with 128 copper atoms in contact with the floor. Press Play and set the photon gun's wavelength and intensity. Vacuum means no added background gas; the chamber still contains the sample.

Selecting an element updates the chamber, atom and electron views together and keeps the current view open. Each new sample starts paused. Copper uses an empirical many-body potential. Other material samples are general references, not calibrated predictions for every element. Sources & model identifies the active model and its limits.

Scale matters. The chamber is nanometres across; time is in femtoseconds or picoseconds. Gravity is real, but bonding dominates here. Colours refer to bulk appearance under white light; individual atoms do not have a paint colour.

The photon gun sets wavelength and irradiance. Open Light spectrum for source absorption, thermal emission and atomic line references. Settings changes the theme and drawing. Readings & files records measurements or loads an element and beam settings. Arrow keys navigate the table; Enter selects. Space plays or pauses in the chamber.

Choose a Photon or Electron gun below any view. Electron mode sets 1–3000 eV and current density; selected H/He collision data show a slower outgoing electron and separate radiative photons. Other elements have no bundled impact cross section. Switching gun type turns it off and starts a fresh atomic ensemble.

The photon logarithmic intensity slider spans 10⁻⁶–10¹⁴ W/m², with Off. Beam settings accepts exact irradiance and sourced atomic resonances. The fixed room-temperature wall mount allows cooling. Sample temperature is a kinetic estimate; a bulk-state label does not establish the phase of this small vacuum sample.

Guide · Privacy

Element specimen

Photograph source ↗ · Licence ↗