Aqueous Reactions Lab ready Choose amounts, then pour either test tube. Model notes · v0.21
YEAR 9 · INTERACTIVE CHEMISTRY Aqueous Reactions Lab
v0.21
0.0 sReady
Thermometer
22.0 °C
Measured reading
Room temperature
22.0 °C
Flask +0.0 °C relative
Temperature change
ΔT = +0.00 °C
From the start
Scale reading
0.00 g
Matter supported by scale
Gas produced
0.00 mL
0.000 g outside
Time
0.0 s
Ready
Classroom sensors: 0.1 °C thermometer and 0.01 g balance.Model range good
Reaction heat
0.000 kJ
Reaction amount
0.000 mmol
0.0% conversion
No-loss prediction
22.00 °C
Adiabatic final temperature
Pressure
1.000 atm

Reaction window

Open system on digital balance

Dosing progress0.0%
Test-tube stationTest tubes ready
Right-click a tube or select Pour
100%
Scroll to zoom · drag to pan · double-click to focus
ROOM SENSOR 22.0 °C 0100200250 mL gas 0.0 / 250 mL at 22.0 °C • about 1 atm collector full • gas venting 0.00 g 2550100150200250 mL 10080604020 AFULL 10080604020 BFULL 020406080100 ENERGY FLOW · WAITING run to measure direction appears after evidence
Inspect or tap
Run the experiment to observe energy transfer.Open boundary
Ready. Set the reactants, then run.
Run time0.0 / 90 s
Playback

Live views

0.0 s
Start22.0 °C
Extreme22.0 °C
Measured ΔT+0.0 °C
90% response—

Temperature vs time

Ready: run the experiment to collect data.
2

Energy evidence

Waiting
Run the reaction
TWatch whether temperature rises or falls.
mWatch whether gas changes the scale reading.
3

Reactant ratio

The equation sets the reacting ratio.
Equation ratio1 : 1
Starting ratio1.00 : 1.00
Runs out first-
Left over0.000 mmol
Maximum extent0.000 mmol
4

Conservation of mass

Starting chemicals are divided between the flask, test tubes and any gas beyond the scale.

0.000 g
Starting mass
=
0.000 g
On scale
+
0.000 g
In test tubes
+
0.000 g
Gas outside
ScaleTest tubesGas outside
Total accounted for = 0.000 g
Check your explanation
Question 1What evidence identifies the energy change?
Run the experiment, then use the direction of the temperature change.
Question 2Why can the scale reading fall?
Gas can move beyond the boundary of the scale.
Question 3Which reactant limits the reaction?
Compare starting amounts with the coefficient ratio.
Advanced data and model

Model values

Enthalpy change, ΔH-57.3 kJ mol-1
Effective rate barrier, Ea*45.0 kJ mol-1
Heat capacity0 J °C-1
Heat loss0.00 W °C-1
Liquid volume0.0 mL
Headspace0.0 mL
Reaction to mixture0.000 kJ
Transferred to room0.000 kJ
Stored thermal change0.000 kJ
Accounting residual0.000 J

The selected setup is within the intended classroom model range.

Recent data

Export the full run as CSV.

Time (s)Thermometer (°C)Liquid model (°C)ΔTExtent (mmol)ProgressReaction q (kJ)Stored ΔE (kJ)Supported mass (g)In test tubes (g)Balance display (g)Gas outside (g)Pressure (atm)
Aqueous Reactions Lab · v0.21

How the model works

The balanced equation sets the reacting ratio. The reaction stops when a reactant runs out, a solubility limit is reached, or the pressure safety limit is triggered.

The thermometer and balance can behave like real classroom instruments: readings have finite resolution and the thermometer takes time to respond. Advanced view can also show the underlying liquid-temperature model.

The bulk liquid, solids and deposits use expected visible colours. Particle markers and graph lines are analytical symbols; they do not represent the colour or true size of individual atoms, ions or molecules.

The live reaction field and flask detail view are two renderings of the same chemical state. Version 17 uses a coarse-grained overdamped Brownian reaction–diffusion model: dissolved species undergo temperature-, concentration- and viscosity-dependent random motion, fluid motion advects them, gas partitioning uses a temperature-dependent Henry-law estimate, and solids behave as surfaces, crystals, deposits or settling precipitate aggregates. Aggregate diffusion uses a morphology-dependent hydrodynamic radius; settling uses a porosity-adjusted Stokes estimate, while gas populations rebalance among dissolved, bubble and headspace phases as temperature and pressure change. Reaction events are synchronised to the calculated macroscopic reaction extent and drawn at the physically relevant site for the selected process.

The field is not molecular dynamics. Marker counts are proportional to calculated amounts, but microscopic distance, particle size, collision frequency and time are magnified so the process can be observed. Electrostatic motion is weak and screened rather than an unscreened Coulomb model. Boundaries are reflecting, and settling, bubble rise and diffusion are scaled educational analogues rather than direct predictions of microscopic position.

The test-tube pour uses a head-dependent drainage approximation: the stream begins strongly, narrows as the liquid level falls, and ends with separate droplets. Surface waves, mixing plumes and energy-flow marks are explanatory graphics rather than computational fluid dynamics.

Warm or cool moving marks show the direction of energy transfer. They are not particles of heat and they do not add mass to the system.

The scale measures matter still supported by it. When gas leaves, the scale can read less even though total mass is unchanged:

starting mass = mass on scale + mass in test tubes + gas outside

Save up to three completed trials to compare temperature curves. A fair comparison changes one variable while the others remain controlled.

Advanced view adds concentration, heat transfer, pressure, sensor response, energy accounting, model limits and CSV data.